Arc Fault Circuit Interrupters (AFCI)it is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.
AFCI Suitable for communication 50Hz, rated voltage 230V, rated current to 63AIn the following lines, it is used to protect the overcurrent of the lines of buildings and similar purposes, and at the same time, it can detect many fire risks caused by the rupture of electrical devices or the aging of wires in advance, and protect against grounding arc faults, parallel arc faults and series arc faults. To a certain extent, the occurrence of fire safety accidents has been reduced, and the safety of people’s lives and property has been effectively protected.

JGAFCI-63-2 zoom

Pairar

JGAFCI-63-3 zoom

Pairar

JGAFCI-63-4 zoom

Pairar

JGAFCI-63-2 zoom

Pairar

JGAFCI-63-1 zoom

Pairar

JGAFCI-63-2
JGAFCI-63-3
JGAFCI-63-4
JGAFCI-63-2
JGAFCI-63-1
Ecrã completo

Interruptores de circuito de falha de arco JGAFCI-63

, , , ,
Arc Fault Circuit Interrupters (AFCI)it is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.
AFCI Suitable for communication 50Hz, rated voltage 230V, rated current to 63AIn the following lines, it is used to protect the overcurrent of the lines of buildings and similar purposes, and at the same time, it can detect many fire risks caused by the rupture of electrical devices or the aging of wires in advance, and protect against grounding arc faults, parallel arc faults and series arc faults. To a certain extent, the occurrence of fire safety accidents has been reduced, and the safety of people’s lives and property has been effectively protected.

Introdução


Arc Fault Circuit Interrupters
Arc Fault Circuit Interrupters

Arc Fault Circuit Interrupters (AFCI)it is assembled by a miniature circuit breaker and an arc fault protection module, and has protection functions such as overload, short circuit, and arc fault protection.

    Arc Fault Circuit Interrupters (AFCI) Suitable for communication 50Hz, rated voltage 230V, rated current to 63AIn the following lines, it is used to protect the over current of the lines of buildings and similar purposes, and at the same time, it can detect many fire risks caused by the rupture of electrical devices or the aging of wires in advance, and protect against grounding arc faults, parallel arc faults and series arc faults. To a certain extent, the occurrence of fire safety accidents has been reduced, and the safety of people’s lives and property has been effectively protected.

AFCI Product features


a)Proteção contra sobrecarga e atrasos longos;

b)Proteção contra sobrecarga e curto-atraso;

c)Proteção de disparo instantâneo;

d)Proteção contra arco elétrico em série;

e)Proteção contra falhas de arco em paralelo;

FGprotecção contra arco voltaico;

g)Múltiplas especificações de corrente.

AFCI working  and installation conditions


aTemperatura ambiente do ar

A temperatura do ar ambiente não é maior+70℃,Não menos que-35℃,24A média das horas não excede+35℃;

Nota: A temperatura do ar ambiente é superior+70℃ou inferior-35℃condições de utilização AFDD A proteção contra falhas de arco está desligada O roader deve ser negociado com o fabricante;

bAltitude:

A altitude do local de instalação não excede 2000m;

cCondições atmosféricas

A umidade relativa da atmosfera está em sua temperatura mais alta nos arredores+60℃tempo não excedido 50%, que pode ter uma fase mais alta em temperaturas mais baixas para umidade, por exemplo, 20℃tempo 90%, para condensação ocasional devido a mudanças de temperatura, medidas de proteção devem ser tomadas;

dCondições de instalação

Protetor de falha de arcoO campo magnético externo próximo ao local de instalação não deve exceder o campo geomagnético em qualquer direção5Fold; A posição de instalação deve ser vertical e a inclinação em todas as direções não deve exceder 10 °; Instalado em um local onde não há vibração de choque e sem chuva ou neve Quadrado; Adote os padrões TH35-7.5 instalação de trilho de instalação de aço de seção;

ePoluição Nível:2 nível

fCategoria de instalação:ⅢTipo;

gProtecção de entrada:IP20(Instalado numa caixa de distribuição, armário de distribuição ou caixa.) IP40);

hCom ele N Aquando da cablagem, o fio neutro deve ser ligado à marca N Identificação dos pólos.

Informações sobre o pacote padrão


 

Dimensão da caixa de cartão (cm) Lista de embalagem QUANTIDADE Peso bruto (kg)